SCADA Data Gateway

Model: SCADA Data Gateway

The SCADA Data Gateway (SDG) is a Windows™ application used by System Integrators and Utilities to collect data from OPC, IEC 60870-6 (TASE.2/ICCP), IEC 61850, IEC 60870-5, DNP3, or Modbus Server/Slave devices and then supplies this data to other control systems supporting OPC, IEC 60870-6 (TASE.2/ICCP) Cl


  • Performs the work of an OPC Server or Protocol Translator.
  • Translate between any number of available protocols.
  • Includes a protocol analyzer.
  • Built in equation editor supports the creation of new data points based on raw data points and /or other equation points.
  • OPC Certified™; Conformance tested per DNP3 Intelligent Electronic Device (IED) Certification Procedure Subset Level2, Rev. 2005).
  • Report by Exception (RBE) is supported (transmitting only data changes, saving communication channel bandwidth).
  • Supports DNP3 Secure Authentication.
  • Supports selective logging of event data into a time-stamped Sequence of Events (SOE) log file.
  • The Communication Protocol Analyzer Window displays and decodes transmitted and received messages.
  • Allows translation between data types and control methods from different protocols. Supports mapping of points between Master and Slave, two Master, and/or two Slave protocol components.
Channel Display. The SDG supports multiple channels, utilizing the same or different protocols.  Mixed channel types (serial, TCP/IP, modem) and Multidrop connections are supported.

Diagnostics Display. Built-in diagnostics includes status information and error counts that are exposed through OPC and can be mapped to a status point in other protocols. Separate diagnostics are available for the entire SDG and for each channel, session, and sector.

Mapping Information Display. All points are automatically mapped to the SDG’s OPC Server. Other mappings are assigned using simple drag and drop operations. Points may be mapped from Master to Slave, Master to Master, or Slave to Slave components.
SDGConfig Window
  • OPC Data Access Server 1.0a, 2.00, 2.05a, and 3.0 (OPC Certified™).
  • OPC Data Access Client 2.00 and 2.05a (OPC Certified™).
  • OPC Alarms and Events 1.00, 1.02, and 1.10 Server (OPC Certified™).
  • OPC Alarms and Events 1.00, 1.02, and 1.10 Client.
  • OPC XML Data Access Server.
  • ODBC Client.
  • DNP3 – Serial and TCP/IP (Conformance tested per DNP3 Intelligent ElectronicDevice (IED) Certification Procedure Subset Level 2, Rev. 2005).
  • IEC 61850 including: 7-410 (Hydro), 7-420 (DER) & 61400-25 (Wind).
  • IEC 60870-6 (TASE.2/ICCP) including Blocks 1, 2, and 5.
  • IEC 60870-5-101 – Basic Telecontrol Tasks.
  • IEC 60870-5-103 Master – Protection Equipment.
  • IEC 60870-5-104 – TCP/IP network access for -101.
  • Modbus Serial ASCII/RTU, Modbus Plus, and Modbus TCP.